  1. Half_burned triac - All About Circuits

    Nov 2, 2024 · Hi, In a dishwasher machine main board we have used 107NN0 triac for controlling ac loads such as valves, pumps, dispenser, etc. In about 2 to 3 percent of products sold to …

  2. Triac light dimmer controlled with DC voltage - All About Circuits

    Aug 4, 2023 · I am looking for a way to make a "light dimmer" (actually controlling a heating coil) using a triac, where I can control the duty cycle of the AC based on a DC voltage. In searching …

  3. Triac burn out - All About Circuits

    Jul 26, 2022 · Triac failures are usually caused by either excess current or excess voltage, either to the gate or through the device, and if they happen at the moment of turn on application it is …

  4. Triac Identification - All About Circuits

    May 26, 2024 · The triac that's connected to the heater T2 (terminals A1 & G), on the diode setting of the multimeter, reads .072, and the other triac T1 reads .037. The triac numbers are:

  5. Using Triac To Power 24VAC Sprinkler Solenoid Valve - Only …

    Jan 18, 2022 · Hello, I made this circuit so I can control a 24VAC sprinkler solenoid valve (rain bird ones from home depot), using a microcontroller. I also want to mention that I am new to …

  6. TRIAC ANALYSIS-Calculation of gate resistor - All About Circuits

    Oct 20, 2016 · The Triac needs a maximum of 10mA gate current, the supply is 230V, so with R1at 10K, R2+3 needs to drop 130V, which gives 13K total at 1.5W.. simple ohms law

  7. Triac low output problem - All About Circuits

    May 1, 2012 · I've got a strange (to me) problem with some interesting scope traces: The circuit is two separate 3023 optoisolators driving two separate triacs, each one powering a large 3 …

  8. Triac for AC motor speed controller | All About Circuits

    Jan 6, 2018 · These use a triac control readily, sometimes a bridge is added. All you need to do to confirm it is to lift or otherwise insulate one brush and measure the motor terminal resistance …

  9. Triac, M1/M2 always interchangeable, or sometimes or what?

    Jun 9, 2020 · Hello, When a triac or thyristor is fired, it needs the voltage to go to almost zero to reset. The triac or thyristor will "reset" below the holding current. Bertus

  10. Triac vs bjt - All About Circuits

    Jun 27, 2017 · Triac's do not have this problem because theoretically the current must be zero when they turn off. You can trick a triac with a transistor, but then you're back to the transistor …